Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35
Filtrar
1.
J. appl. oral sci ; 15(1): 9-13, Jan.-Feb. 2007. ilus, tab
Artigo em Inglês | LILACS | ID: lil-450003

RESUMO

A group of destructive changes occurring in jaws in patients with maxillary complete dentures and mandibular removable partial dentures (bilaterally) has been described in the literature as the combination syndrome. However, this condition is not clinically observed in all patients. The aim of this study was to establish the prevalence index on signs of combination syndrome and to verify whether these changes also occurred in patients rehabilitated with a mandibular removable partial denture (unilaterally). Sample was composed of 44 patients, completely edentulous in the maxilla. Thirty-two patients had a Kennedy Class I removable partial denture and 12 a Kennedy Class II. Three major alterations were observed in 20.5 percent of the studied population. Nevertheless, these changes were present only in 25 percent of patients with Kennedy Class I removable partial denture. Based on the findings of this study, it can be concluded that patients with Kennedy Class II removable partial denture do not have similar signs that lead to the combination syndrome's condition.

2.
J Appl Oral Sci ; 15(1): 9-13, 2007 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-19089092

RESUMO

A group of destructive changes occurring in jaws in patients with maxillary complete dentures and mandibular removable partial dentures (bilaterally) has been described in the literature as the combination syndrome. However, this condition is not clinically observed in all patients. The aim of this study was to establish the prevalence index on signs of combination syndrome and to verify whether these changes also occurred in patients rehabilitated with a mandibular removable partial denture (unilaterally). Sample was composed of 44 patients, completely edentulous in the maxilla. Thirty-two patients had a Kennedy Class I removable partial denture and 12 a Kennedy Class II. Three major alterations were observed in 20.5% of the studied population. Nevertheless, these changes were present only in 25% of patients with Kennedy Class I removable partial denture. Based on the findings of this study, it can be concluded that patients with Kennedy Class II removable partial denture do not have similar signs that lead to the combination syndrome's condition.

3.
Rev. ABO nac ; 14(4): 242-247, ago.-set. 2006. tab, graf
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-544739

RESUMO

Introdução - Há muito se apresentam tentativas para estabelecer padrões de resinas e técnicas de processamento ideais para obtenção de bases protéticas; com os resultados biológicos positivos dos implantes osseointegrados e, mais recente ainda, com a execução de trabalhos protéticos realizados imediatamente, algo em torno de 12 ou 24 horas pós-cirúrgico, uma variável tornou-se importante, que é o tempo de trabalho laboratorial. Este trabalho avaliou comparativamente as características físicas, estabilidade dimensional e absorção de água, de resinas acrílica, consideradas de polimerização rápida, utilizadas para bases de próteses implanto-retidas e implanto-suportadas, em função imediata, quais sejam: uma fotopolimerizável (Vercyo.com), uma ativada através de microondas (Acrom - MC), uma termopolimerizável em água (Impact - Bosworth) e outra termopolimerizável (Lucitone 199), pelo método convencional (grupo controle). Materiais e Método - O manuseamento dos materiais se realizou de acordo com as orientações dos fabricantes. Foram confeccionados 10 corpos de prova de cada resina acrílica, em cinco matrizes metálicas (discos), com dimensões de 25x10x2 mm e um orifício central de 10 mm de diâmetro e os resultados foram analisados, estatisticamente, através do Teste de Análise de Variância a um critério e o Teste de Tukey, para comparação entre as médias. Resultados - Os resultados mostraram que as resinas apresentaram diferenças, estatisticamente significante, tanto para o teste de absorção de água quanto para estabilidade dimensional linear. Conclusão - A resina do Grupo B apresentou as características físicas avaliadas, com diferenças estatísticas significantes em relação às outras resinas.


Introduction - Several attempts have been made to establish patterns of ideal resins and processing techniques, for achievement of prosthetic bases. With the positive biological outcomes of osseointegrated implants and, more recently, with the accomplishment of immediate prosthetic rehabilitations, at 12 to 24 hours postoperatively, a variable has become important, which is the laboratory time. This study comparatively evaluated the physical characteristics, dimensional stability and water absorption of fast-curing acrylic resins employed for fabrication of implant-retained and implant-supported prosthetic bases with immediate function, as follows: one light-cured (Vercyo.com), one microwave-cured (Acrom - MC), one heat-cured in water (Impact - Bosworth) and one heat-cured (Lucitone 199), by the conventional method (control group). Materials and Method - Handling of the materials followed the manufacturers' instructions. Ten specimens were fabricated from each acrylic resin, in five metallic templates (discs), with dimensions of 25x10x2 mm and a central orifice with 10 mm diameter; results were statistically analyzed by one-way analysis of variance and the Tukey Test, for comparison between the means. Results - The results demonstrated that the resins presented statistically significant differences for both water absorption and dimensional linear stability. Conclusion - The resin in Group B presented the physical characteristics evaluated, with statistically significant differences compared to the other resins.


Assuntos
Prótese Dentária , Implantes Dentários , Teste de Materiais , Polímeros , Resinas Acrílicas/análise
4.
Rev. odonto ciênc ; 21(53): 261-265, jul.-set. 2006. ilus
Artigo em Inglês | LILACS, BBO - Odontologia | ID: lil-457367

RESUMO

Introdução: Nas moldagens para obtenção de modelos para confecção de próteses, principalmente quando são realizadas em áreas retentivas da boca, resíduos de saliva e sangue ficam retidos no material e podem conter microoganismos patogênicos. Somente a lavagem do molde em água corrente não garante que todo sangue e microoganismos aderidos à superfície do molde tenham sido eliminados. Assim torna-se necessária a desinfecção dos moldes para a qual os métodos de desinfecção spray e imersão têm sido testados com várias soluções desinfetantes e provaram sua eficiência para esse propósito. No entanto, esse procedimento pode afetar a estabilidade dimensional do material de moldagem. Objetivo: Este estudo objetivou avaliar a estabilidade dimensional dos materiais de moldagem após a imersão em soluções desinfetantes de hipoclorito de sódio 1% e glutaraldeído 2%. Material e métodos: Foram realizadas 45 moldagens para cada um dos materiais: poliéter (Impregun F®), polissulfetos (Permlastic®), e hidrocolóide irreversível (Hydrogun®). 40 moldes de cada material foram imersos nas soluções desinfetantes variando-se o tempo entre 10 e 15 minutos. 10 moldes foram imersos em glutaraldeído a 2% por 10 min, 10 por 15 min, outras 10 imersos em hipoclorito de sódio a 1% por 10 min, e 10 por 15 min. Os demais moldes 5 não foram imersos em nenhum desinfetante e serviram como grupo controle. Resultados: Nos moldes obtidos foram medidas as distâncias (AB, CD, AC, BD) em um microscópio digital Mitutoyo (TM 500) e os resultados foram submetidos à análise de variância a 2 critérios e as diferenças pelo teste de Tukey com intervalo de confiança de 95%. A análise dos resultados mostrou que não houve diferenças estatísticas significantes para os moldes de poliéter e polissulfeto quando comparados ao grupo controle. No entanto, para os moldes de alginato desinfetados em hipoclorito de sódio a 1% por 15 min, observou-se uma distorção estatisticamente significante quando comparado ao grupo cont...


Assuntos
Desinfecção/métodos , Desinfetantes/efeitos adversos , Glutaral/administração & dosagem , Hipoclorito de Sódio/administração & dosagem , Materiais para Moldagem Odontológica
5.
UFES rev. odontol ; 8(1): 37-45, jan.-abr. 2006. ilus, tab
Artigo em Português | LILACS, BBO - Odontologia | ID: biblio-873033

RESUMO

Há muito se apresentam tentativas para estabelecer padrões de resinas e técnicas de processamento ideais para obtenção de bases protéticas. Com os resultados biológicos positivos dos implantes ósseos integrados e, mais recente ainda, com a execução de trabalhos protéticos realizados imediatamente, em torno de 12 ou 24 horas, pós-cirúrgico, uma variável tornou-se importante, que é o tempo de trabalho laboratorial. Esta pesquisa avaliou comparativamente as características mecânicas de rugosidade e resistência flexional de resinas acrílicas, utilizadas para bases de próteses implanto-retidas e implanto-suportadas, em função imediata, quais sejam: uma fotopolimerizável (Vercyo.com), uma ativada por meio de microondas (Acron - MC), uma termopolimerizável de ciclo rápido em água (Impact - Bosworth) e outra termopolimerizável (Lucitone 199), pelo método convencional (grupo controle). O manuseamento dos materiais ocorreu de acordo com as orientações dos fabricantes. Foram confeccionados dez corpos-de-prova de cada resina acrílica, em matrizes de silicona laboratorial, com dimensões de acordo com a Especificação 12 da ADA e os resultados foram analisados, estatisticamente, pelo Teste de Análise de Variância a um critério e o Teste de Tukey, para comparação entre as médias. Os resultados mostraram que as resinas apresentaram diferenças, estatisticamente significantes, tanto para o teste de rugosidade quanto para resistência flexional. A resina do Grupo B (Impact - Bosworth) apresentou as características mecânicas avaliadas, com diferenças estatísticas significantes em relação às outras resinas. Com relação à resistência flexional, as quatro resinas apresentaram diferenças estatísticas significantes. Os melhores resultados foram apresentados pela resina fotopolimerizável testada (Grupo V - Vercyo.com).


Assuntos
Resinas Acrílicas , Prótese Dentária Fixada por Implante , Bases de Dentadura
6.
Rev. odonto ciênc ; 20(50): 319-323, out.-dez. 2005. ilus, tab
Artigo em Inglês | LILACS, BBO - Odontologia | ID: lil-436390

RESUMO

Introdução: Nas moldagens para obtenção de modelos para confecção de próteses, principalmente quando são realizadas em áreas retentivas da boca, resíduos de saliva e sangue ficam retidos no material e podem conter microoganismos patogênicos. Somente a lavagem do molde em água corrente não garante que todo sangue e microorganismos aderidos à superfície do molde tenham sido eliminados. Assim torna-se necessária a desinfecção dos moldes para a qual os métodos de desinfecção spray e imersão têm sido testados com várias soluções desinfetantes e provaram sua eficiência para esse propósito. No entanto, esse procedimento pode afetar a estabilidade dimensional do material de moldagem. Objetivo: Este estudo objetivou avaliar a estabilidade dimensional dos materiais de moldagem após a imersão em soluções desinfetantes de hipoclorito de sódio 1% e glutaraldeído 2%. Material e métodos: Foram realizadas 45 moldagens para cada um dos materiais: poliéter (Impregun F), polissulfetos (Permlastic R), e hidrocolóide irreversível (Hydrogun). 40 moldes de cada material foram imersos nas soluções desinfetantes variando-se o tempo entre 10 e 15 minutos. 10 moldes foram imersos em glutaraldeído a 2% por 10 min, 10 por 15 min, outras 10 imersos em hipoclorito de sódio a 1% por 10 min, e 10 por 15 min. Os demais moldes 5 não foram imersas em nenhum desinfetante e serviram como grupo controle. Resultados: Nos moldes obtidos foram medidas as distâncias (AB, CD, AC, BD) em um microscópio digital Mitutoyo (TM 500) e os resultados foram submetidos à análise de variância a 2 critérios e as diferenças pelo teste de Tukey com intervalo de confiança de 95%. A análise dos resultados mostrou que não houve diferenças estatísticas significantes para os moldes de poliéter e polissulfeto quando comparados ao grupo controle. No entanto, para os moldes de alginato desinfetados em hipoclorito de sódio a 1% por 15 min, observou-se uma distorção estatisticamente significante quando comparado ao grupo cont...


Assuntos
Desinfecção , Glutaral/administração & dosagem , Hipoclorito de Sódio/administração & dosagem , Materiais para Moldagem Odontológica
7.
J. appl. oral sci ; 12(3): 244-249, July-Sept. 2004. ilus, tab
Artigo em Inglês | LILACS, BBO - Odontologia | ID: lil-392463

RESUMO

O objetivo deste trabalho foi avaliar a estabilidade dimensional das siliconas de condensação pesada e leve para moldagem odontológica, quando imersas em solução desinfetante por 10 e 20 minutos, relacionando a importância da biossegurança no manuseio destes materiais. Os materiais de moldagem testados foram: Optosil Confort e Xantopren VL Plus; e as soluções desinfetantes foram o hipoclorito de sódio a 1% (Solução de Milton) e o glutaraldeído a 2% (Glutaron II). Impressões foram obtidas através de moldeiras perfuradas de aço inoxidável, de acordo com a especificação n.º 19 da ADA, perfazendo um total de 50 moldagens, que foram executadas pela técnica em passo único. Para assegurar a completa polimerização o material foi removido após 7 minutos e submetido à imersão nas soluções desinfetantes nos tempos determinados, sendo um grupo controle representado por moldes sem imersão. Depois de removidos das soluções, os corpos de prova foram lavados em água corrente por 15 segundos, secos e medidos 3 vezes cada para registro da média, usando um microscópio óptico, com precisão de 0,001 mm. A análise de variância a dois critérios, com nível de significância de 5%, mostrou que as diferenças nas dimensões lineares da silicona testada não são estatisticamente significantes (p>0,05) após sua imersão em solução de hipoclorito de sódio a 1% e glutaraldeído a 2% até 20 minutos. Os resultados indicaram que as soluções testadas podem ser seguramente empregadas na desinfecção de siliconas de adição durante os procedimentos clínicos de reabilitação protética.


Assuntos
Desinfetantes de Equipamento Odontológico , Elastômeros de Silicone , Materiais para Moldagem Odontológica , Técnica de Moldagem Odontológica , /métodos
8.
Artigo em Inglês | MEDLINE | ID: mdl-14716267

RESUMO

OBJECTIVE: This study evaluated the condyle-disc relationship on magnetic resonance image (MRI) in a group of subjects with silent temporomandibular joints (TMJs) when tested clinically with those in subjects with discernible temporomandibular sounds. Study design Twenty-five completely edentulous patients were selected to participate in this study. The study was based on bilateral MRIs of 15 patients (with articular sound) and 10 symptom-free volunteers (control). RESULTS: It was noted that disc displacement was found in 45% of the TMJs with no history of articular sounds. In 6 TMJs of control group, a reducing disc displacement was found, and in 3 TMJs a permanent displacement was found. Disc displacements were identified in 70% of patients. Reducing disc displacement was found in 19 of these TMJs, whereas permanent displacement was found in 2 TMJs. In 9 of the joints of the symptomatic group, a superior disc position was found. Also verified was a significant association between reducing disc displacement and biconvex disc. CONCLUSION: These observations demonstrated that internal derangements can not be associated to clicking joints or symptoms of temporomandibular disorders in elderly edentulous patients, and the presence of displaced discs seems to be associated to altered disc morphology, but not to osseous abnormalities.


Assuntos
Prótese Total , Côndilo Mandibular/patologia , Boca Edêntula/patologia , Disco da Articulação Temporomandibular/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Distribuição de Qui-Quadrado , Feminino , Humanos , Luxações Articulares/diagnóstico , Instabilidade Articular/diagnóstico , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Som , Articulação Temporomandibular/patologia , Transtornos da Articulação Temporomandibular/diagnóstico
9.
J Appl Oral Sci ; 12(3): 244-9, 2004 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21049261

RESUMO

The purpose of this study was to evaluate the dimensional stability of heavy and light bodied condensation silicones after immersion in disinfectant solution for 10 or 20 minutes. The impression materials were Optosil Comfort and Xantopren VL Plus and the disinfectant solutions were 1% sodium hypochlorite and 2% glutaraldehyde. Impressions were made on a perforated stainless steel tray, according to the American Dental Association specification No. 19, adding up to a total of 50 samples. The double mixing method (one time, two viscosities) was used. Impressions were removed from the roulette block after 7 minutes to ensure complete curing and then immersed in the solutions. Impressions not submitted to treatment composed the control group. After these steps, the impressions were removed from the solution, rinsed in running water and air-dried. Three-dimensional measurements were calculated using an optic microscope graduated at 0.001 mm. The two-way ANOVA indicated no differences (p>0.05) for any combination between variables. The results showed that the solution studied can be safely used to disinfect condensation silicone in clinical prosthodontic procedures.

10.
JBA, J. Bras. ATM Oclusão Dor Orofac ; 3(10): 141-4, abr.-jun. 2003. graf, CD-ROM
Artigo em Português | BBO - Odontologia | ID: biblio-851474

RESUMO

O objetivo do presente estudo foi avaliar a prevalência de sinais e sintomas de DTM em pacientes portadores de prótese total, quando comparados a um grupo de indivíduos dentados. A possível associação com o tempo de uso das próteses e qualidade das mesmas também foi avaliada. A amostra foi constituída de 100 indivíduos (média de idade de 44,4 anos), igualmente divididos em dois grupos: Grupo 1, pacientes portadores de prótese total, e Grupo 2, pacientes dentados. Todos os indivíduos foram solicitados a responder um questionário anamnésico, que deu origem a um índice anamnésico de DTM. Palpação muscular e da ATM, análises da movimentação mandibular, da condição oclusal e das características das próteses também foram realizadas. Testes de associação de qui-quadrado e correlação de Spearman, com nível de significância de 5 por cento, verificaram as hipóteses propostas. Sintomas de DTM moderada e severa foram encontrados em 40 por cento do grupo com PT, enquanto somente 12 por cento do grupo dentado apresentavam tal condição (p<0,05). A presença de sinais, no entanto, não foi estatisticamente diferente entre os grupos. A presença de estalidos articulares e discrepâncias maxilomandibulares, também foi mais prevalente no grupo com PT (p<0,05). Não foi encontrada, todavia, correlação entre o tempo de uso das próteses e a presença ou severidade de DTM. Os resultados indicam uma maior prevalência de sintomas de DTM no grupo portador de PT, apesar disto não se relacionar a características específicas das próteses. Tais achados devem ser avaliados com cautela devido à flutuação natural dos sintomas de DTM


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Epidemiologia
11.
Rev. Assoc. Paul. Cir. Dent ; 56(6): 460-464, nov.-dez. 2002. ilus, tab, graf
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-331324

RESUMO

Sessenta pré-molares extraídos foram divididos em 6 grupos (recebendo grampos "T" e "I", sobre superfícies de esmalte, amálgama e resina composta), para avaliar a resistência dos grampos ao deslocamento sobre as diferentes superfícies. Realizaram-se testes de remoçäo e inserçäo numa máquina de costura adaptada, em ciclos de 6 meses, 1, 2, 3, 4 e 5 anos. Inicialmente e após os testes, corpos-de-prova foram pesados em balança de precisäo. Os grampos "T" apresentaram maior resistência ao deslocamento do que os grampos "I". Ambos apresentaram perda de retençäo (em ordem crescente) em esmalte, amálgama e resina composta. Houve diferença estatisticamente significante em relaçäo à perda de peso nas superfícies de resina composta, quando comparadas às de esmalte e amálgama


Assuntos
Resinas Compostas , Amálgama Dentário , Grampos Dentários , Esmalte Dentário
12.
Rev. Fac. Odontol. Bauru ; 10(3): 186-194, jul.-set. 2002. tab, graf
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-329385

RESUMO

Um dos procedimentos indicados para dentes avulsionados e que seräo reimplantados após trinta minutos fora do alvéolo é o tratamento da superfície radicular. Mesmo com a eliminaçäo do ligamento periodontal ressecado ou danificado e limpeza do canal radicular, os casos de insucessos säo enormes. Frente a isso, este trabalho tem como objetivo tratar a superfície radicular de dentes de ratos avulsionados e reimplantados tardiamente. Para isso, foram utilizados 54 dentes incisivos centrais superiores direitos de ratos, divididos em três grupos. No grupo I, a superfície radicular foi tratada com soluçäo de hipoclorito de sódio a 1 por cento; no grupo II, com soluçäo de hipoclorito de sódio a 1 por cento seguido da aplicaçäo de fluoreto de sódio a 2 por cento; no grupo III, após o uso do hipoclorito de sódio a 1 por cento, foi utilizada a soluçäo de acetazolamida a 5 por cento. Todos os grupos tiveram seus canais preenchidos com pasta de hidróxido de cálcio e, em seguida, os dentes foram reimplantados em seus alvéolos. Passados 15, 60 e 90 dias do reimplante, os animais foram mortos e as peças obtidas, processadas em laboratório para análise em microscópio de luz. Os resultados mostraram que todos os tratamentos testados näo impediram a ocorrência da anquilose e da reabsorçäo radicular


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Disco da Articulação Temporomandibular/fisiopatologia , Idoso de 80 Anos ou mais , Prótese Total , Imageamento por Ressonância Magnética/métodos , Transtornos da Articulação Temporomandibular/diagnóstico
13.
Rev. Fac. Odontol. Bauru ; 10(2): 81-87, abr.-jun. 2002. tab
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-329359

RESUMO

Avaliou-se a posiçäo e deslocamentos condilares antes e após instalaçäo de PT,s novas, por meio de planigrafias laterais da ATM. O critério de seleçäo dos pacientes foi aleatório e, mediante a amostra, foram preenchidos um questionário clínico-anamnésico, seguido de tomadas radiográficas com o par de dentaduras antigas e novas em 12 pacientes. Um único examinador conduziu o preenchimento das fichas e análise das radiografias no programa de imagens Corel Draw 8. De acordo com a metodologia aplicada e análise estatística dos resultados, verificou-se que a posiçäo condilar em desdentados totais na primeira tomada radiográfica situou-se mais para anterior em 100 por cento dos casos. Já o deslocamento condilar após instalaçäo das novas próteses resultou em uma tendência de deslocamento para posterior em 75 por cento dos indivíduos, para anterior em 16,7 por cento e em 8,3 por cento näo houve variaçäo da posiçäo condilar. Dos 18 côndilos com deslocamento para posterior, após a instalaçäo dos novos pares de PT,s, apenas 1 côndilo assumiu uma posiçäo levemente posterior, tendo os demais se localizado concentricamente ou para anterior. Näo houve correlaçäo estatística entre variaçöes das posiçöes condilares e dimensöes verticais de oclusäo. A posiçäo condilar nos desdentados está situada mais para anterior na fossa glenóide e a tendência de localizaçäo para posterior possivelmente näo iräo causar danos aos pacientes, tendo em vista se tratarem de indivíduos assintomáticos


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Articulação Temporomandibular , Idoso de 80 Anos ou mais , Diagnóstico por Imagem , Côndilo Mandibular , Transtornos da Articulação Temporomandibular
14.
Rev. Fac. Odontol. Bauru ; 9(3/4): 105-111, jul.-dez. 2001. ilus, tab, graf
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-321814

RESUMO

As alteraçöes da dimensäo vertical de oclusäo em dentaduras completas, foram avaliadas por meio do processamento do método de cura por microondas, a partir de 30 corpos de prova e três tipos diferentes de resinas acrílicas dentais termopolimerizáveis: Onda Cryl resina própria para microondas; resina terrmopolimerizável convencional da Clássico, e Acron Mc, todas processadas em forno caseiro de microondas, com a potência de 800 Watts pelo seguinte ciclo: três minutos a uma potência máxima de 40 por cento da capacidade máxima; quatro minutos a uma potência de 0 por cento da capacidade (pausa), e três minutos a uma potência máxima de 90 por cento da capacidade máxima. As dentaduras padronizadas remontadas e reposicionadas no articulador Dentatus, foram avaliadas em relógio micrométrico com ponteiro calibrador e micrômetro digital, ambos acoplados ao pino guia do articulador. As médias encontradas e submetidas à análise estatística demonstraram que houve diferença significante entre as amostras. Todas as amostras sofreram alteraçäo da dimensäo vertical de oclusäo, sendo que o método sugerido apresentou facilidade, rapidez, näo necessitando de aparelhos complicados e amplamente favorável ao uso dos laboratórios de prótese


Assuntos
Prótese Total , Micro-Ondas , Dimensão Vertical , Resinas Acrílicas , Oclusão Dentária , Prótese Dentária
15.
Rev. Fac. Odontol. Bauru ; 7(3/4): 33-7, jul.-dez. 1999. ilus, tab
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-298404

RESUMO

A borracha vulcanizada descoberta por Charles Goodyear em 1839 teve grande utilizaçäo na confecçäo de bases de dentaduras até 1936, quando entäo apareceu a resina acrílica para preencher a lacuna estética, e assim alguns problemas foram resolvidos, outros ainda permaneceram como: ciclo incorreto, movimentaçäo dental, alteraçöes dimensionais, dentre outras, diante disto, verificou-se as possíveis alteraçöes dimensionais ocorridas com uma resina acrílica ativada termicamente após polimerizaçäo, por 3 diferentes técnicas, respectivamente denominadas 1) de Tuckfield, 2) de Laboratório, e 3) sob Pressäo. Para esta finalidade, foram construídas 10 muflas padräo, com 10 corpos de prova em cada técnica empregada, totalizando assim 30 corpos de prova padronizados. Apesar de ocorrerem alteraçöes dimensionais por contraçäo de polimerizaçäo entre todas as técnicas descritas, pelas análise estatística concluiu-se que: na aplicaçäo dos testes de Tukey a nível de 5 por cento, ocorreu diferença significante somente entre as técnicas T (de Tuckfield) e P (de Pressäo)


Assuntos
Resinas Acrílicas/classificação , Resinas Acrílicas/metabolismo , Materiais Dentários/classificação , Materiais Dentários/metabolismo , Materiais Dentários/química , Resinas Acrílicas/química
16.
PCL ; 1(3): 212-214, 1999. ilus, CD-ROM
Artigo em Português | BBO - Odontologia | ID: biblio-853197

RESUMO

A técnica de poliemarização por microondas da resina acrílica para base de dentaduras foi submetida a diversos experimentos analisando suas qualidades e possibilidades de uso clínico, o correndo algumas conclusões contraditórias, talvez pelo fato de não se estabelecerem os mesmos critérios experimentais com: Forno de microondas, quantidade e tipo de amostragem. Mesmo assim, de maneira geral, o uso da energia de microondas é viável clinicamente


Assuntos
Resinas Acrílicas , Prótese Total , Micro-Ondas , Polímeros
17.
PCL ; 1(1): 40-44, 1999. ilus, CD-ROM
Artigo em Português | BBO - Odontologia | ID: biblio-853182

RESUMO

Os autores apresentam uma breve revisão de literatura e um caso clínico onde foram confeccionadas dentaduras completas pelos métodos de polimerização convencional e por radiação de microondas. As próteses processadas por microondas tornam-se uma alternativa reduzindo o tempo de trabalho e não necessitando de materiais sofisticados para sua confecção


Assuntos
Humanos , Resinas Acrílicas , Prótese Total , Prótese Dentária , Micro-Ondas
18.
In. Vanzillotta, Paulo Sérgio; Salgado, Luiz Paulo dos Santos. Odontologia integrada: atualizaçäo multidisciplinar para o clínico e o especialista. Rio de Janeiro, Pedro Primeiro, 1.ed; 1999. p.257-69, ilus.
Monografia em Português | LILACS, BBO - Odontologia | ID: lil-250809
19.
Rev. Fac. Odontol. Bauru ; 6(2): 53-65, abr.-jun. 1998. ilus, tab
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-256199

RESUMO

Estudou-se em 120 indivíduos, metade dentados e os demais portadores de dentaduras completas, entre outras características, a largura do nariz em repouso e sua correlaçäo com a distância intercaninos, medida de cúspide a cúspide, em linha reta. Uma técnica de projeçäo da largura nasal (PANC) foi comparada com a técnica de projeçäo das comissuras labiais, para escolha da largura dos dentes. Analisou-se ainda a regiäo de incidência da linha intercuspídea canina sobre a papila incisiva, nos dentados. Finalmente, foram analisadas duas tabelas de modelos de dentes artificiais encontradas no comércio. Com base nos resultados, dentro das condiçöes estabelecidas, concluiu-se o seguinte: näo é adequado se estabelecer correlaçäo entre a largura do nariz em repouso e a distância intercaninos, medida de cúspide a cúspide, em linha reta; confirmou-s e o método PANC como mais adequado que o de projeçäo das comissuras labiais; existem dentados nos quais a largura dos seis dentes ântero-superiores é maior que a medida máxima dos artificiais disponíveis no mercado; a linha intercuspídea canina superior incidiu sobre a papila incisiva, no seu terço posterior, em 63,666 por cento dos dentados; há forte evidência de que, nas próteses totais superiores, os dentes foram escolhidos com largura menor que o adequado, para o sexo masculino


Assuntos
Humanos , Masculino , Feminino , Adulto , Adolescente , Dente Artificial/classificação , Dente Artificial/provisão & distribuição , Boca Edêntula/terapia , Planejamento de Prótese Dentária/efeitos adversos , Planejamento de Prótese Dentária/métodos , Planejamento de Prótese Dentária/normas , Prótese Total
20.
Rev. Fac. Odontol. Bauru ; 6(2): 67-72, abr.-jun. 1998. tab, graf
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-256200

RESUMO

Avaliou-se as alteraçöes dimensionais de três marcas de resinas acrílicas termopolimerizáveis quando processadas em forno de microondas convencional, a uma potência média alta (500 a 630W), durante três minutos. As leituras foram feitas imediatamente após a polimerizaçäo e depois de sete dias imersas em água destilada em temperatura ambiente. Constatou-se que näo houve diferença significante entre as resinas Palaton e Acrom-MC, porém a resina Lucitone 199, apresentou alteraçäo significante maior que as outras duas, tanto na primeira como na segunda leituras. O fator tempo foi determinante e todas as amostras sofreram contraçäo imediata e expansäo higroscópica após sete dias. As diferenças existentes provavelmente estejam relacionadas com a composiçäo das resinas e a forma de polimerizaçäo a que foram submetidas


Assuntos
Micro-Ondas , Resinas Acrílicas/metabolismo , Materiais Dentários/classificação , Materiais Dentários/metabolismo , Materiais Dentários/química , Resinas Acrílicas/classificação , Resinas Acrílicas/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...